Sterile Manufacturing Vessel is designed to produce sterile solutions in accordance with USFDA and WHO guidelines. This vessel is fully enclosed, with an agitator situated above its dome. This tank can be customized with a standard or magnetic stirrer, depending on the needs of the user, for a variety of applications.
Sterile Manufacturing Vessel Video
Salient Features of Sterile Manufacturing Vessel
- Design as per ASME code.
- No stagnant point, internal surfaces are 0.28 Ra finish.
- All contact parts/surfaces made out of SS 316/SS 316L quality.
- Electro polished from inside.
- The vessel will be jacketed, insulated and cladded by SS 304 sheet.
- Spray ball for CIP/SIP system.
- Flush bottom valve.
- Steam/Electrical heating.
- If required, Load cell/capacitance type level indicator will be provided to measure the volume inside the tank.
Process Operation of Sterile Manufacturing Vessel
Jacketed Mixing Vessel (double jacketed vessel) including jacketed steam boiler is uses for mixing liquid and slightly solid materials. Jacketed Mixer assembly equipped with series of paddles types blades, pitched or flat blade of appropriate shape. In Mixer two consecutive blades move in opposite direction which creates laminar thinning of the material and facilitates uniform mixing. Paddle type blades mounted on scrapping arms and welded to hollow shaft have independent drive. Bottom support to the shaft called piyot provided for firmness of shaft during rotations. Paddles mounted on internal shaft creates relative movement of the material. For discharge of material different types of valves can be offered as per user requirements.
Technical Specification of Sterile Manufacturing Vessel
Description | Specification |
Capacity | 5 Liters to 20000 Liters |
Power Supply | 0.5 H. P. to 75 H. P. |
Power Voltage | 440 volts, 3 phase, 50 hertz |
Gearbox | Helical type / similar |
Stirrer Type | Pitch Type Stirrer |
Stirrer MOC | Stainless Steel 304/316/316L |
Stirrer RPM | 150 RPM adjustable through VFD |
Stirrer Mounting Orientation | Top Mounted |
No. of blades | Two |
Shaft Diameter | Suitable Diameter |
* Power voltage can be adjusted as per customer’s domestic power voltage requirements.
* Rights of technical improvements & modification reserved.
* Illustrations & dimensions are shown for information purpose only.